Sign In | Join Free | My qualitytoyschina.com
China Hangzhou Qianrong Automation Equipment Co.,Ltd logo
Hangzhou Qianrong Automation Equipment Co.,Ltd
Hangzhou Qianrong Automation Equipment Co.,Ltd. focus on ultrasonic application, in good faith to win customers
Verified Supplier

7 Years

Home > Ultrasonic Welding Converter >

Replacement Telsonic 35khz Ultrasound Cutting Transducer

Hangzhou Qianrong Automation Equipment Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Replacement Telsonic 35khz Ultrasound Cutting Transducer

Brand Name : QRsonic

Model Number : QR-T35

Certification : CE

Place of Origin : China

MOQ : 1 pcs

Price : Negotation

Payment Terms : T/T, Western Union

Supply Ability : 2000pcs per month

Delivery Time : 3 workdays

Packaging Details : Packed in carton

Products Name : Ultrasonic Replacement Konverter

Frequency : 35 khz

Output power : 1200 watt

Joint bolt : M8

Ceramic disc Diameter : 25mm

Capacitance : 2100-2300pf

Amplitude : 6um

Application : Ultrasonic Cutter

Contact Now

Replacement Telsonic 35Khz Ultrasound Cutting Transducer for Ultra Cutter

Description:

QRsonic adopts QM value, technical strength, low strong field loss, high power density, low mechanical dielectric loss, high piezoelectric coupling coefficient, stable performance piezoelectric ceramic sheet, through the precise structure design, and the parameters of the ceramic sheet are highly consistent. Accurate, corrosion-resistant, non-rusting, 62 phosphor copper with excellent conductivity, assembled into an ultrasonic transducer with strong stability and long service life.

Repacement Telsonic SE3512C Konverter. Ultrasonic transducer is a device that can convert high-frequency electrical energy into mechanical energy. It is generally magnetostrictive and piezoelectric ceramic. The power output is sent to the ultrasonic generator, and then to the ultrasonic transducer. The ultrasonic derivation device can generate ultrasonic waves.

Specifications:

Model QR-T35
Frequency 35 khz
Output power 1200 watt
Joint bolt M8
Ceramic disc Diameter 25mm
Qty of ceramic discs 4pcs
Capacitance 2100-2300pf
Amplitude 6 um
Application Ultrasonic Cutter

Specification:

Item No

Connect screw (Size)

Ceramic diameter (mm)

Quantity of Ceramic (pc)

Resonance frequency (khz)

Input Power Machine
1-QR-BCJ20 1/2-20UNF 50 6 20 3300

Branson

2000 series

2-QR-BCR20 1/2-20UNF 50 6 20 3300

Branson

2000 series

3-QR-B502 1/2-20UNF 50 4 20 2000

Branson

5170, 8800

4-QR-B402 1/2-20UNF 40 4 20 900

Branson

8200, 8400

5-QR-B803 1/2-20UNF 50 4 20 2000

Branson

8700

6-QR-B902J 1/2-20UNF 50 4 20 2000

Branson

910W or IW+

7-QR-B4TH M8 25 4 40 800 40khz Branson welders
8-QR-B4TR M8 25 4 40 800 40khz Branson welders
9-QR-D20 1/2-20UNF 50 2 20 2000 20khz Dukane Heavy Duty
10-QR-D41S30 1/2-20UNF 50 4 20 2000 Dukane model 43A250, 43A255, 43D255, 43E255, 43A260, or 43B260
11-QR-D41C30 1/2-20UNF 50 4 20 2000
12-QR-D110-3122 1/2-20UNF 50 4 20 2000
13-QR-D110-3168 1/2-20UNF 50 4 20 2000 Dukane Model 43B18
14-QR-D41C28 M8 35 2 40 800 40khz Dukane welders
15-QR-D41C29 M8 35 2 40 800 40khz Dukane welders
16-QR-R3510 M8 25 4 35 800 35Khz Rinco Welders
17-QR-R35 M8*1.25 25 2 35 500 35khz Rico Welders
18-QR-R20 1/2-20UNF 50 2 20 1200
19-QR-J3506 M8 25 4 35 800
20-QR-J3710 M8 25 4 37 500 CV231
21-QR-J3706-W1 M8 25 4 37 500
22-QR-J3706-W2 M8 32 2 37 400 CV3510
23-QR-T35 M8 25 4 35 800 35khz Telsonic Machine
24-QR-H20 1/2-20UNF 50 6 20 3000

Special Items can be customized.

The reasons why the transducer is often bad are:

1. The power loss of the transducer itself is large, and the transducer needs to consume a certain amount of power when vibrating. This loss power directly reflects the quality and process of the transducer, and the power consumed by the transducer itself is as small as possible. The greater the loss power, the greater the damage. In severe cases, the piezoelectric ceramic is directly broken. The amount of power loss directly reflects the process and quality of the transducer.

2. The aluminum alloy horn of the transducer is fatigue fracture (affected by the material life), and the amplitude is large.

3. The piezoelectric ceramic piece of the transducer is broken (by the piezoelectric ceramic itself, the mechanical strength causes loss and heat, overload and high power output, loose)

Piezoelectric Effect 35khz 1000w Ultrasonic Transducers Replacement Convertor Telsonic

Replacement Telsonic 35khz Ultrasound Cutting Transducer

Replacement Telsonic 35khz Ultrasound Cutting Transducer


Product Tags:

35khz ultrasonic cutting transducer

      

35khz ultrasound cutting transducer

      

replacement telsonic ultrasound cutting transducer

      
Quality Replacement Telsonic 35khz Ultrasound Cutting Transducer wholesale

Replacement Telsonic 35khz Ultrasound Cutting Transducer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hangzhou Qianrong Automation Equipment Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)